• 0813-1111-0220
  • 0813-6111-6112
  • This email address is being protected from spambots. You need JavaScript enabled to view it.

Datasheet Produk

Kidde Fire Protection - UL Certificate GAQF.EX5054 Clean Agent Extinguishing System Units

229 Downloads

GAQF.EX5054 - Clean Agent Extinguishing System Units

Clean Agent Extinguishing System Units

 

See General Information for Clean-agent Extinguishing System Units

KIDDE FIRE PROTECTION
1st Floor, Stokenchurch House
Oxford Road
High Wycombe
Stokenchurch, Buckinghamshire HP14 3SX
UNITED KINGDOM

 

ENGINEERED UNITS
Models E7763-101, E7763-102, E7763-103, E7763-104, E7763-105, E7763-106, E7763-107, E7763-108, E7763-109, E7763-110, E7763-111, E7763-112, and E7763-113, GX-20 Clean Agent Extinguishing System Units, stored pressure type, having nominal charging capacities of 5, 8, 16, 28, 51, 81, 81, 142, 142, 243, 243, 368 and 368 liters of FM-200 Clean Agent, respectively. The units are super-pressurized to 25 bar with operating temperatures of -0 C to +54 C. The units are designed for total flooding protection against Class A surface burning, Class B flammable liquid and Class C fires occurring within an enclosure.

These systems are intended to be designed and installed in accordance with the Listee's Design, Installation, Operation and Maintenance Manual, P/N 59812-422, Issue C, dated November 2004. These installations require the use of the Listee's Flow Calculation Software, Version GX3.03 (reference Software User's Manual P/N E9832-014, Issue B, dated November 2004). Copies are available from the Listee.

Last Updated on 2015-04-22.


The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright noticein the following format: "© 2021 UL LLC"

File Name: kidde-fire-protection-ul-certificate-GAQF.EX5054-clean-agent-extinguishing-system-units.pdf
Category: Kidde Fire Systems
File Size:
File Type: application/pdf
Kunjungan: 1016 Kunjungan
Download: 229 kali
Last Updated: 14-05-2021

Dokumen Serupa

Kidde-Fenwal, Inc - UL Certificate GOYW.EX4674 Clean Agent Extinguishing System Units, Marine
Kidde-Fenwal, Inc - UL Certificate GOYW.EX4674 Clean Agent Extinguishing System Units, Marine

UL Underwriters Laboratories, Inc. Certificate - GOYW.EX4674 Clean Agent Extinguishing System Units, Marine.

Kidde-Fenwal, Inc - UL Certificate GAQFC.EX4674 Clean Agent Extinguishing System Units
Kidde-Fenwal, Inc - UL Certificate GAQFC.EX4674 Clean Agent Extinguishing System Units

UL Underwriters Laboratories, Inc. Certificate - GAQFC.EX4674 Clean Agent Extinguishing System Units.

Kidde-Fenwal, Inc - US Coast Guard Certificate of Approval 162161_1 FM200 Total Flooding Clean Agent Fixed Fire Extinguishing Systems [Renewal]
Kidde-Fenwal, Inc - US Coast Guard Certificate of Approval 162161_1 FM200 Total Flooding Clean Agent Fixed Fire Extinguishing Systems [Renewal]

U.S. Coast Guard Certification - Kidde-Fenwal, Inc. HFC-227ea total flooding clean agent fixed fire extinguishing systems. ECS series systems for the protection of machinery spaces, cargo pump rooms, and other enclosed spaces.

Kidde-Fenwal, Inc - UL Certificate GAQF.EX4674 Clean Agent Extinguishing System Units
Kidde-Fenwal, Inc - UL Certificate GAQF.EX4674 Clean Agent Extinguishing System Units

UL Underwriters Laboratories, Inc. Certificate - GAQF.EX4674 Clean Agent Extinguishing System Units.

Kidde-Fenwal - Det Norske Veritas [DNV GL] F-20253 - Type Approval Certificate Approved for Use as Total Flooding Fire Extinguishing System in Machinery Spaces and Cargo Pump Rooms - Minimum Design Gas Concentration 8.7%
Kidde-Fenwal - Det Norske Veritas [DNV GL] F-20253 - Type Approval Certificate Approved for Use as Total Flooding Fire Extinguishing System in Machinery Spaces and Cargo Pump Rooms - Minimum Design Gas Concentration 8.7%

U.S. Coast Guard Certificate Kidde-Fenwal, Inc - HFC-227ea total flooding clean agent fixed fire extinguishing systems. ECS series systems for the protection of machinery spaces, cargo pump rooms, and other enclosed spaces.

Kidde Fire Systems - American Bureau of Shipping [ABS] 03-HS357143-4-PDA - Confirmation of Product Type Approval ECS Suppression System Marine Series with HFC-227ea Agent
Kidde Fire Systems - American Bureau of Shipping [ABS] 03-HS357143-4-PDA - Confirmation of Product Type Approval ECS Suppression System Marine Series with HFC-227ea Agent

Kidde-Fenwal, Inc. Total Flooding Clean Agent FM-200 Engineered Fire Suppression System, Marine ECS Series. Machinery Space, Cargo Pump Rooms & Other Enclosed Spaces.

Kunjungi Kami
alamat kantor ReedFOX Fire & Life Safety Indonesia
Padamin FM200 Fire Suppression System
Hubungi kami sekarang juga!
0813-1111-0220
small-logo.png
small-logo.png
Hubungi kami sekarang juga!
0813-1111-0220