SELECTABLE CANDELA EVACUATION SIGNALS
APPLICATIONS
The Fike Selectable Candela Evacuation Signals, manufactured by Gentex Corporation, are low profile horn, strobe or horn/strobe combination that offer dependable audible and visual alarms and the lowest current available.
The Fike Selectable Candela Evacuation Strobe Horn/Strobe 24VDC offers field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers selectable candela options of 15, 30, 60, and 75 candela.
Evacuation horn offers a continuous or synchable temporal 3 in 2400Hz and mechanical tone, a chime as well as a whoop tone. All tones are easy for the professional to change in the field by using switches. The Horn Strobe is shipped from the factory on the temporal lower frequency mode and it comes standard with a rugged cast metal mounting plate.
The Fike Selectable Candela Evacuation Signals have a minimal operation current and a minimum flash rate of 1Hz regardless of input voltage.
Units also come standard with the 4" mounting plate which incorporates the popular SuperSlide feature that allows you to easily test for supervision. Also included is a locking mechanism which secures the product to the bracket without any screws showing.
Appliances are UL 464 and UL 1971, listed for use with fire protective systems and are warranted for three years from date of purchase.
STANDARD FEATURES
• 24 VDC units have field selectable candela options of 15, 30, 60, 75, and 110 candela
• 12 VDC units have field selectable candela options of 15, 30, 60, and 75 candela
• The horn is available in 12 or 24 Volt
• Prewire Entire System, Then Install Your Signals
• Ease of Supervision Testing (SuperSlide)
• Lower Installation and Operating Costs
• Input Terminals 12 to 18 AWG
• Switch Selection for High or Low dBA
• Switch for Chime, Whoop, Mechanical and 2400Hz Tone
• Switch for Continuous or Temporal 3 (not available on whoop tone)
• Tamperproof Re-entrant Grill
• Surface Mount with the Surface Mount Box
• Synchronize Strobe and/or Horn by Using the AVS Series Control Module
• Silence Horn While Strobes Remain Flashing
• Rugged Die Cast Metal Mounting Bracket
• True Evacuation Tone
• Wide Voltage Range 8-17.5 VDC (12 Volt Models) 16-33 VDC or FWR (24 Volt Models)
• Available in Red or Off-White
APPROVALS
• Americans with Disabilities Act (ADA 4.28.3)
• BFP (City of Chicago)
• BS+A/MEA #285-91-E
• CSFM 7135-0569:122 (Horn Strobe); 7125-0569:123 (Strobe)
• FM Approved
• NFPA 72
• UL ULC Dual Listed 464, 1971
ARCHITECT AND ENGINEERING SPECIFICATIONS
The audible and/or visible signal shall be a Gentex Selectable Candela Evacuation Signal or approved equal and shall be listed by Underwriters Laboratories Inc. per UL 1971 and/or UL 464. The notification appliance shall also be listed with the California State Fire Marshall (CSFM) and the Bureau of Standards and Appeals (NYC).
The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at 12 or 24V as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized.
Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel.
The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or greater regardless of power input voltage. The appliance shall have an operating current of 55mA or less at 12 or 24 VDC for the 15Cd strobe circuit.
The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 volts for 12 volt models.
The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box.
File Name: | fike-horn-strobe-evacuation-signals-alarm-conventional-P.1.62.01-1.pdf |
Category: | Fike |
File Size: | |
File Type: | application/pdf |
Kunjungan: | 787 Kunjungan |
Download: | 122 kali |
Last Updated: | 01-06-2021 |
Cheetah XI 50 Intelligent Panel FM200 Suppression Control System
CIE-A-200 Addressable Control Panel Fire Alarm System
Supervisory Control Module Fire Alarm System
Conventional Zone Module Fire Alarm System
Breakglass Manual Call Point Conventional Fire Alarm System
Photoelectric Smoke Detector Conventional